beautypg.com

Additional decode features, Code bytes 0–9 – Posiflex MS-5145 User Manual

Page 20

background image

20

116600

Disable Tab Suffix

Additional Decode Features

Minimum Symbol Length – Single-line default is 3 digit,

Combine this code with the proper code bytes (on page

16–1), to specify the minimum number of characters in all

non-UPC/EAN bar codes.

901800

Symbol Length Lock – Combine this code with the proper

code bytes, to lock the bar code’s length into place.

901900

The features that use this code byte for Configuration require

that the scanner be in configuration mode. The Enter/Exit

Configuration Mode bar code must be scanned before

starting the configuration cycle.

Example:User configurable Minimum Characters can then

be saved in to the scanner by scanning the appropriate

code byte character barcodes.

To Program Minimum Symbol Length to one

1. Enter/Exit Configuration Mode (3 beeps)

2. Configurable Prefix (1 beep)

3. Code Byte 0 (1 beep)

4. Code Byte 1 (2 beeps)

5. Enter/Exit Configuration Mode (3 beeps

Code Bytes 0–9

3

1 1 6 6 0 0

3

9 0 1 8 0 0

3

9 0 1 9 0 0

3

0

Code Byte 0

3

1

Code Byte 1