Symptoms

Possible Causes

Solution

The unit powers
up, but does not
scan and/or
beep.

The unit is trying to
scan a particular
symbology that is

not enabled.

UPC/EAN, Code 39,

interleaved 2 of 5,

Code 93, Code 128

and Codabar are

enabled by default.

Verify the type of

bar code being

read has been

selected.

The unit powers
up, but does not
scan and/or
beep.

The bar code being

scanned does not

satisfy the con-

figured criteria for

character length

lock or minimum

length.

Verify the bar code

being scanned falls

into the configured

criteria. The scanner

defaults to a mini-

mum of three-

character bar code.

TTL RS232 & Serial Emulation USB Interfaces

The unit scans

a bar code, but

locks up after

the first scan

and the red LED
stays on.

The unit is con-

figured to support

some form of host

handshaking but is

not receiving the

signal.

If the unit is setup to

support ACK/NAK,

RTS/CTS, XON/

XOFF or D/E, verify

that the host cable

and host are

supporting the

handshaking properly.

The unit scans,

but the data

transmitted to the
host is incorrect.

The unit’s data

format does not

match the host

system’s

requirements.

Verify the unit’s data

format matches that

required by the host.

Make sure that the

unit is connected to

the proper host port.

The bar code may

have been printed

incorrectly.

The unit is not

configured correctly

for the type of bar

code being scanned.

Check if it is a
check digit/
character/or border
problem.

The unit beeps

at some bar
codes but NOT
for others of the
same bar code
symbology.

The minimum

symbol length setting

does not work with

the bar code.

Check if the correct

minimum symbol

length is set.

Keyboard Wedge Interface

The unit scans

the bar code but

there is no data.

The unit’s

configuration is not

correct.

Make sure the scanner

is configured for the

appropriate mode.