5.Front Panel Operation

34

Note: The length of file name is up to 15 characters.

To Set the Utility Function

Press Utility function key to enter the Utility Menu. You can set the parameters of the
Generator such as: Display Parameter, Counter Parameter, Output Parameter and System
Setting. Press Utility again to exit the Utility Menu.

To Set Display Parameter

To Set the Bright

(1)

Press Utility and choose Disp Setup, press F1 to select Bright.

(2)

Turn the knob to change the value, press

/

direction key to move the cursor

left and right; or press the number keys to input the desired value in percent, press

F4

to select the unit. The bright range is 0% - 100%.

To Set the Separator

The user can set the separator of the displayed parameter.

(1)

Press Utility and choose Disp Setup, press F2 to select Sep.

(2)

Press F2 to switch between Comma, Space, Off.

Take the Frequency parameter for instance:

Comma

Space

Off

To Set the Screen Saver

The screen saver will run automatically if no operation is taken for any key within the set
time. Press any button to resume.

(1)

Press Utility and choose Disp Setup, press F3 to select Scrn Svr.

(2)

Press F3 to switch between On/Off.

(3)

If On is selected, you can set the screen saver time. Turn the knob to change the
value, press

/

direction key to move the cursor left and right; or press the

number keys to input the desired time in minutes, press F4 to select the unit.
The screen saver time range is 1 - 999 minutes.