Osburn OB01111 User Manual
Page 9
9
CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR
To install your appliance correctly, it is extremely important to respect all clearances to any
combustibles as indicated on your stove’s certification label.
Clearances to combustible materials
(see figure 1.3 to match each letter to a clearance)
CLEARANCES (SINGLE WALL PIPE)
CANADA
USA
A
20" (508 mm)
20" (508 mm)
B
16" (406 mm)
16" (406 mm)
C
14" (356 mm)
14" (356 mm)
D
21" (533 mm)
21" (533 mm)
E
25" (635 mm)
25" (635 mm)
F
19" (482 mm)
19" (482 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
CLEARANCES (DOUBLE WALL PIPE)
CANADA
USA
ALCOVE
CANADA / USA
MOBILE HOME
CANADA / USA
A
12" (305 mm)
12" (305 mm)
13" (330 mm)
12" (305 mm)
B
17" (432 mm)
17" (432 mm)
13" (330 mm)
17" (432 mm)
C
6" (152 mm)
6" (152 mm)
-
6" (152 mm)
D
13" (330 mm)
13" (330 mm)
14" (356 mm)
13" (330 mm)
E
26" (660 mm)
26" (660 mm)
22" (559 mm)
26" (660 mm)
F
11" (279 mm)
11" (279 mm)
-
11" (279 mm)
K
48" (1220 mm)
48" (1220 mm)
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
84" (213 cm)
84" (213 cm)