MANUFACTURED (MOBILE) HOME INSTALLATIONS – ADDITIONAL
REQUIREMENTS
1. The stove must be bolted to the floor (secure the unit by prying out the two plastic
plugs in the pedestal, and installing the two 3/8" x 3-1/2" (9.8mm x 88.9mm) lag
bolts through the holes provided).
2. The unit
must
be provided with outside combustion air.
3. Clearance from the top of stove to an unprotected ceiling should be a minimum of
52” (1321mm).
4. The stove must be used connected to the chimney with listed double wall connector
of 6" (152 mm) diameter.
5. The chimney system must be a minimum of 12' (3658 mm) in height from the
hearth pad to the top of the chimney assembly.
Figure1.1 Necessary installation components.
Note: For manufactured home installations in the USA, the stove must be grounded to the
frame of the home using a # 8 ground wire with approved terminations and star lock
washers.