Overview, System manager ts, Smts technical guide 4 features – Orion System OE392-10 System Manager TS User Manual
Page 4: System requirements

Zone
Zone
Overview
SMTS Technical Guide
4
Features
The OE392-10 System Manager TS (Touch Screen) provides a direct,
graphic-enhanced, menu-driven link to enable you to view the status and
adjust the setpoints of most controllers on the Orion Controls System.
(See Figure 1.)
The System Manager TS provides the following useful functions:
• Provides a 4.3” 480 x 272 WQVGA RGB TFT LCD Graphical
Touch Screen LCD display with 16 million colors
• Utilizes a graphical touch screen menu system with easy-
to-understand menu trees and icons and non-cryptic, plain
English language messages
• Makes entering data quick and easy with instructions on each
confi guration and setpoint screen
• Graphic programming and status screens provide easy setup
and operation without the need for specialized training
• Provides protection from unauthorized users through integral
multi-level passcode authorization programming
• Comes equipped with real-time clock backup power supply
for short power losses
• Can be updated with software updates downloaded from the
Orion Controls website—www.orioncontrols.com—using a
USB-Link or CommLink
• Provides icon to indicate alarm conditions
• LEDs behind plastic panel indicate power, communications,
and operation
• Plastic enclosure allows for easy fl ush wall mounting in
hollow drywall or surface mounting on solid wall surface
System Manager TS
System Requirements
• The System Manager TS is packaged and assembled as fl ush
wall mount. Surface mount components are also included for
your
convenience.
• If using the surface mount version, you will need a double
duplex outlet box (by others).
•
The System Manager TS only works with the following VAV/
Zone Controller EPROMs: SS1001, SS1005, SS1025
•
The System Manager TS only works with the following VCM,
VCM-X, VCM-X Modular, VCM-X WSHP, and VCB-X
Controller EPROMs: All standard SS1016, SS1026, SS1030,
SS1032, SS1033, SS1034, SS1051 and later
*• USB-Link, CommLink, or MiniLink Polling Device
*
NOTE:
Alarm polling must fi rst be set up in Prism II. This requires
a personal computer with Prism II software and a USB-Link
or CommLink and a MiniLink Polling Device. Ongoing
alarm polling on the System Manager TS Main Screen
requires a MiniLink to be connected to the system.
NOTE:
Screens in this manual referring to VCM-X also apply
to VCM controllers.
Figure 1: System Manager TS