beautypg.com

ONICON F-5100 Insertion User Manual

Page 17

background image

11451 Belcher Road South, Largo, FL 33773 • USA • Tel +1 (727) 447-6140 • Fax (727) 442-5699 • [email protected]

F-5100 Insertion Thermal Mass Flow Meter Manual 05/15 - 0663-20 / 18333

Page 17

Tightening the Compression Fitting

1.

Insert the sensor as described above.

2.

Tighten the nut until the stem will not turn by hand or

move axially in the fitting.

3.

Mark the nut at the 6 o’clock position.

4.

While holding the fitting body steady, tighten the nut one

and one quarter (1¼) turns to the 9 o’clock position.

CAUTION

The compression fitting must be tightened as described in the following procedure. Failure to do

will likely result in fluid leaks and/or permanent damage to the flow sensor stem.

!

Collar

Collar

For high pressure kits, position upper collar as shown and
then tighten both collars to complete the installation.