Warning flags – Olson Technology MUSCLE-EM55X User Manual
Page 65
OTOT-EM55X/XL Optical Transmitter Rev. x1
www.olsontech.com
64
Index
Flag
Description
31
RESERVED
Reserved for the NMS Controller (Do not use these bits)
Flags in bold letters can be controlled via the limits menu.
Warning Flags
Index
Flag
Description
0
OUTPUT_PWR_LOW_WARNING
Optical output power is lower than the warning limit
1
LASER_HIGH_WARNING
The laser current of one laser is higher than the warning limit
2
TEC_HIGH_WARNING
The Peltier current of one laser is higher than the warning limit
3
RF_INPUT_LOW_WARNING
RF signal is lower than the warning limit
4
POWER_SUPPLY_WARNING
One of two power supplies fails (obsolete)
5
FAN_LEFT_WARNING
The left fan (looking from device's front side) fails
6
FAN_RIGHT_WARNING
The right fan (looking from device's front side) fails
7
OUTPUT_PWR_HIGH_WARNING
Optical output power is higher than the warning limit
8
RF_INPUT_HIGH_WARNING RF
signal
is higher than the warning limit
...
12
POWER_SUPPLY_LEFT_WARNING
The left power supplies (looking from device's front side) fails
13
POWER_SUPPLY_RIGHT_WARNING
The right power supplies (looking from device's front side) fails
14
OMI_OR_RFGAIN_LOW_WARNING
The calculated RF gain (if AGC on) or the calculated OMI (if AGC
off) is lower than the warning limit
15
OMI_OR_RFGAIN_HIGH_WARNING
The calculated RF gain (AGC on) or the calculated OMI (AGC off) is
higher than the warning limit
16
+3.3V_LOW_WARNING
Supply +3.3V is lower than the warning limit
17
+3.3V_HIGH_WARNING
Supply +3.3V is higher than the warning limit
18
+5V_LOW_WARNING
Supply +5V is lower than the warning limit
19
+5V_HIGH_WARNING Supply
+5V
is
higher than the warning limit
20
-5V_LOW_WARNING Supply
-5V
is
lower than the warning limit
21
-5V_HIGH_WARNING Supply
-5V
is
higher than the warning limit
22
+12V_LOW_WARNING
Supply +12V is lower than the warning limit
23
+12V_HIGH_WARNING
Supply +12V is higher than the warning limit
24
-12V_LOW_WARNING Supply
-12V
is lower than the warning limit
25
-12V_HIGH_WARNING Supply
-12V
is higher than the warning limit
26
N/A N/A
27
N/A N/A
28
LASER_TEMP_DIFF_LOW_WARNING
Laser temperature difference from nominal value is lower than the
warning limit
29
LASER_TEMP_DIFF_HIGH_WARNING Laser temperature difference from nominal value is higher than the
warning limit
30
MODULE_TEMP_LOW_WARNING Module
temperature is lower than the warning limit
31
MODULE_TEMP_HIGH_WARNING Module temperature is higher than the warning limit
Situations triggering a warning flag in the OTOT-EM55X; Flags in bold letters can be controlled via the limits menu.