OTOT-EM55X/XL Optical Transmitter Rev. x1
www.olsontech.com
63
Figure 51 — Setting the Event Mask for the Webserver and SNMP Interface of OTOT-EM55X
With this feature all warnings / alarms of the OTOT-EM55X can be either enabled or disabled by the user in relation to
the LED’s on the front panel, the Webserver status screen and SNMP interface. If the alarm/warning mask is applied a
notify message will be shown on the status menu screen.
Note: If the NEC software of a transmitter is upgraded to Rev. 1.9 or later, the OTOT-EM55X firmware might not sup-
port the alarm/warning flag mask, which means, that the LED’s on the front panel might not reflect the alarm/warning
masks.
Alarm Flags
Index
Flag
Description
0
TEC_HIGH_ALARM
Peltier current is higher than the alarm limit (Laser switched off)
1
OUTPUT_PWR_LOW_ALARM
Optical output power is lower than the alarm limit
2
RF_INPUT_LOW_ALARM
RF signal is lower than the alarm limit
3
OUTPUT_PWR_HIGH_ALARM
Optical output power is higher than the alarm limit
4
RF_INPUT_HIGH_ALARM
RF signal is higher than the alarm limit
5
OMI_OR_RFGAIN_LOW_ALARM
The calculated RF gain (if AGC on) or the calculated OMI (if AGC
off) is lower than the alarm limit
6
OMI_OR_RFGAIN_HIGH_ALARM
The calculated RF gain (AGC on) or the calculated OMI (AGC off) is
higher than the alarm limit
...
28
MODULE_TEMP_LOW_ALARM Module
temperature is lower than the alarm limit
29
MODULE_TEMP_HIGH_ALARM Module
temperature is higher than the alarm limit
30
RESERVED
Reserved for the NMS Controller (Do not use these bits)