The potential errors that may be displayed are:
Invalid Command – The command was not recognized
Invalid Parameter – The parameter was not recognized
Invalid Value – The value was invalid for the command/parameter
Missing Parameter – A required parameter was not provided
Each command response will have the following format:
where msg is as described above and in the commands summary and example tables below. Note that a
response is enveloped by leading and trailing
Due to the inherent collisions that can occur between multiple addressed units operating on a shared
serial bus, a remote processor should not send a subsequent command to any unit until it has received
the response to the last command it sent to any other. For this reason, the address of a unit is not
included in its response as it is not needed by the remote processor, and thus, the command response
format for a unit remains the same whether or not the unit is operating in addressed mode.
Table 2-2: Commands Summary
Command
Param-Value
Pairs
Response Format
(enveloping
getident
None
ok pn
where:
unaddressed mode
only) or no (SSPA only)
getstatus
None
ok fault
where:
Bit3 = Power fault (1=fault condition present, 0=no fault)
Bit2 = PLL fault (1=PLL fault condition present, 0=no fault; this bit
used only for BUC)
Bit1 = Over temperature fault (1=fault condition present, 0=no fault)
Bit0 = Output mute fault (1=unit muted, 0=unit not muted)