3 configuration, 1 address setting on each frame, 3configuration – Nevion FR202 User Manual
Page 9
FR-2RU-20-2
Rev. A
nevion.com | 9
3
Configuration
3.1 Address setting on each frame
Each frame can be assigned an address through the rotary switches on the rear. Maximum
8 frame addresses (0-7) are available
, this means that pos. “8” and “9” on the rotary switch
are not valid
This address setting only applies when the frame is used in combination with a GYDA-SC
Rack System Controller.
If you have more than 8 frames together, you need several GYDA-SC Rack System
Controller cards.
In order to ensure proper operation of the system, it is important that no frames
controlled by the same GYDA-SC Rack System Controller card have the same
address set.
Reset the frame after reconfiguring the frame system, by turning the power off
and on again.
Figure 4: Rotary switch
More detailed information on the RS-422 configuration can be found in a separate
document and at our web site:
Valid positions: 0-7