beautypg.com

8 frame status (leds), 1 multicon – Nevion FR202 User Manual

Page 24

background image

FR-2RU-20-2

Rev. A


nevion.com | 24

5.8 Frame status (LEDs)

PSU status is presented in the following ways:

Symbol Green LED

Yellow LED

Red LED

No LED

PSU module

none

Power is OK

Voltage or
current alarm

Power
off

Frame front

Power is OK

Communication
problem with
fan front*

Voltage or
current alarm

Power
off**

Temperature
/fans are OK

Communication
problem with
fan front*

Temperature
/fans alarm

Power
off**

*

Lack of communication with PSU in non-

RP mode or one of the PSU’s in RP mode.

(In both situations the fans will have permanent maximum speed)

**

PSU in non-RP mode

or both of the PSU’s in RP mode

5.8.1 Multicon

-

Multicon GUI which presents the following information

o Measured voltages

o Measured currents at each frame voltage

o Total provided power

o Internal PSU temperature

o Alarm status for;

 voltages

 currents

 total provided power

 temperature

 Defect fan

Figure 28: Example of PSU interface in Multicon

-

GPI

o

See description in chapter “GPI Power Supply Status outputs”.