C event input configuration, Cevent input configuration – NavCom RT-3020 Rev.D User Manual
Page 47

RT-3020 User Guide - Rev. E
C
Event Input Configuration
Figure D1 details the wiring of the Event/Can cable
assembly NavCom part number P/N 94-310062-3003.
Refer to Chapter 2, Event for detailed electrical
specifications.
Table D1 details the wiring configuration required for
Event-Hi, and Event-Lo pulse sensing.
Figure C1: Event Cable Wiring Diagram
Pin #
Signal
Name
Event Sync Wiring
1
Event Lo
Tie Event-Hi to Ground
2
Event Hi
Tie Event-Lo to Ground
3 Ground
N/A
Table C1: Event Wiring Connections
Once the cable is wired to correspond with the event
pulse requirements, the receiver must be configured to
output the message containing a time mark, referenced
to the time kept within the receiver, indicating when
the event is sensed.
C-45