beautypg.com

Chapter 6 installation & adjustment – MultiDyne CTV-2000-FRX User Manual

Page 16

background image

CTV-2000 Series Broadcast Transmitter Users’ Manual (REV 1.0)

16

Chapter 5 Accessory

12V DC Adaptor: 1pcs
Users’ Manual: 1pcs

Chapter 6 Installation & Adjustment

6.1 Opening the cover

6.1.1 Inspect the package. If there is any damage or watermark, please contact the freight company or

MULTIDYNE.

6.1.2 After unpacking, check equipments and accessories according to packing list. Any question, please

contact local dealer or MULTIDYNE.

6.1.3 If you think equipment has been damaged, please don’t turn on the power and contact local dealer or

MULTIDYNE.

6.2 Apparatuses & Tools

An optical power meter

A digital multimeter

A frequency analyzer

A standard fiber test jumper (FC/APC or SC/APC or SC/UPC)

Waterless alcohol and nosocomial degrease cotton

6.3 Installation

c. Check input optical power with optical power meter. Making sure that the input power in the range

of -2dBm~-8dBm. -5dBm optical power input is recommended.

d. Insert the input fiber cable to the fiber input port. Clean the connector. Fix the fiber connector with

the fiber adaptor after confirming the input optical power is normal.

e. Connect the RF output port with coaxial cable. The optical receiver installation is finished.

Troubleshooting during installation

a) RF Output Low: check the connection of RF adaptor and the coaxial cable.

b) No RF Output: check the power indicator. If power is on, check the optical input power in the

recommended range.

c) Cautions:

1)

There might be invisible laser beam from fiber pigtail, which might cause permanent injury to