18 Technical data

Max. guide numbers at ISO 100/21°,
zoom 200 mm:

In the metric system: 64
In the imperial system: 210

Flash modes:

ETTL automatic A, strobe flash mode, manual M, Remote slave flash
mode, Servo mode.

automatic aperture setting at ISO 100/21°:

F1.4 to F64, including intermediate values

Manual partial light output levels:

P1/1 . . . P1/ 256 in one-third increments.

P1/1 . . . P1/256 light output, in automatic high-speed synchronisation
(HSS)

Flash durations: see table 2, page (Page 317)

Colour temperature: Ca. 5600 K

Sensitivity to light: ISO 6 to ISO 51200

Synchronisation:

low-voltage ignition

Synchronisation:

Low-voltage ignition

Number of flashes at full light output

• 140 when operating with alkaline-manganese dry cell batteries

(1,5V)

• 190 when operating with nickel-metal-hydride batteries (1,2V /

2100 mAh)

• 290 when operating with lithium batteries (1,5V)

• 360 when operating with external power supply with Metz Power

Pack P76

Recycling times in Sek. (min./max.)

• 0,1/4,4 when operating with alkaline-manganese dry cell batteries

(1,5V)

• 0,1/1,8 when operating with nickel-metal-hydride batteries

(1,2V / 2100 mAh)

• 0,1/4,2 when operating with lithium batteries (1,5V)

• 0,1/1,6 when operating with external power supply with Metz

Power Pack P76

Light coverage:

Reflector from 24 mm (35 mm format)

Reflector with wide-angle diffuser from 12 mm (35 mm format)

Swivelling ranges and locking positions of the reflector:

upwards: -9° 45° 60° 75° 90°

counter-clockwise:
60° 90° 120° 150° 180°

clockwise:
60° 90° 120°

Dimensions, approx., in mm (W x H x D):

Ca. 78 x 148 x 112

Weight :

Flash unit without batteries approx. 422 g

Included:

Flash unit with integrated wide-angle diffuser, operating instructi-
ons, Flash unit mounting foot S60, Belt pouch T64, operating
instructions.