Metro Mobile Computing Workstations MPS-3111 Series Sealed Lead Acid Power Supply User Manual
Page 26

26
Metro
TM
MPS-3111 Series SLA Power Supply Operations Manual Supplement
InterMetro Industries Corporation
3. With the Power Supply away from the workstation, remove the top cover by removing the
two Phillips screws on either side near the top of the case.
Remove Screws from Top Cover
4. Inside the case, locate the two retaining nuts on the sides of the SLA battery. Using the nut
driver, remove the nuts from the screw posts.
Remove Nuts Holding SLA Battery
5. Unplug the battery harness, push down on connector as shown and pull away from the logic
board.
Unplug Battery Harness