Counter section, Environmental, Counter section -2 – Measurement Computing USB-1096HFS User Manual
Page 21: Environmental -2
![background image](https://www.manualsdir.com/files/797897/content/doc021.png)
USB-1096HFS User's Guide
Specifications
Note 1:
The daisy chain power output option allows multiple MCC USB Series boards with a USB hub output port
to be powered from a single external power source in a daisy chain fashion.
The voltage drop between the input of one module and its daisy chain output is 0.5 V maximum. You should
plan for this voltage drop when configuring a daisy chain system to assure functionality of the last board in the
chain.
Counter section
Table 4. Counter specifications
Pin name (Note 2)
CTR
Counter type
Event counter
Number of channels
1
Input type
TTL, rising edge triggered
Input source
CTR screw terminal
Resolution 32
bits
Schmidt trigger hysteresis
20 mV to 100 mV
Input leakage current
±1 µA
Maximum input frequency
1 MHz
High pulse width
500 ns min
Low pulse width
500 ns min
Input high voltage
4.0 V min, 5.5 V absolute max
Input low voltage
1.0 V max, –0.5 V absolute min
Note 2:
CTR is a Schmitt trigger input protected with a 1.5 K Ohm series resistor.
Environmental
Graph 1.Operating temperature de-rating curve (Note 3)
Power Vs. Ambient
0
1
2
3
4
5
6
7
8
0
10
15
20
25
30
35
40
45
50
55
60
65
70
Temperature (C)
Po
w
er
(
W
)
4-2