2.3 OUTPUT RANGE SELECTION

The analog output full-scale ranges are set by DIP switches. Each analog channel has a separate set of switches. The location of the
switches and the channels they control are shown in the Figures 2-2.

CIO-DAC04/12-HS

Figure 2-2. CIO-DAC04/12-HS Switch Locations

Table 2-1 CIO-DAC04/12-HS Range Switch Settings

OFF

ON

OFF

OFF

0 to 2.5V

ON

OFF

OFF

OFF

0 to 5V

OFF

OFF

OFF

OFF

0 to 10V

OFF

ON

ON

ON

+/-2.5V

ON

OFF

ON

ON

+/-5V

OFF

OFF

ON

ON

+/-10V

S4

S3

S2

S1

OUTPUT FULL - SCALE RANGE

NOTE: UP = ON, DOWN = OFF