beautypg.com

Pump pressure adjustment – Dyna-Glo RMC-KFA210T User Manual

Page 16

background image

15

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

I

.) PUMP PRESSURE ADJUSTMENT

- Remove pressure gauge plug from end filter cover.
- Install accessory pressure gauge.
- Start heater (See Operation, page 8)

Allow motor to reach full speed

- Adjust pressure (Using a flat blade screwdriver)

Turn relief valve to right to increase pressure. Turn
relief valve to left to decrease pressure. Set pump
pressure below correct for pressure for each model.

- Stop heater (See Operation, page 9)
- Remove pressure gauge. Replace pressure gauge

plug in end filter cover.

NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.

Use of alternate or third party components will void any warranty and may cause unsafe
operation condition.

Pressure Gauge

Plug

Relief Valve

Pressure Gauge

MODEL

PUMP PRESSURE

RMC-KFA45T

2.8 psi

RMC-KFA65T

3.5 psi

RMC-KFA120T

4.5 psi

RMC-KFA170T

6.5 psi

RMC-KFA210T

8.5 psi