12

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

(For RMC-KFA 210T Models Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove ignitor wire from spark plug.
- Remove spark plug from bracket-spark using medium

phillips screwdriver.

- Clean and regap spark plug electrodes to 3.5mm gap.(0.138 )
- ReInstall spark plug in bracket-spark.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.

G.) PHOTOCELL

CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
(For RMC-KFA 45T/65T/120T/170T Models Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove photocell from it’s mounting.

Clean photocell lens with cotton swab.
TO REPLACE: Remove side cover near

on/off switch.

- Disconnect wires from circuit board and

remove photocell.

- Install new photocell and attach wires to

circuit board.

- Replace fan and upper shell.

Figure 16.

Figure 17.

Side cover

circuit board

Photocell
wires

Photocell

Install Photocell

1)Incorrect

2)Correct

Photocell

lens

(For RMC-KFA 210T Model Only)
- Remove upper shell (See page 9).
- Remove fan (See page 10).
- Remove photocell from it’s mounting.

Clean photocell lens with cotton swab.
TO REPLACE : Remove side cover

opposite on/off switch.

- Disconnect wires from circuit board and

remove photocell.

- Install new photocell and attach wires to

circuit board.

- Replace fan and upper shell.

Figure 18.

Photocell

Install Photocell

1)Incorrect

2)Correct

Photocell

lens

circuit board

Side cover

Photocell
wires

Bracket Burner

Bracket Spark

Spark Plug

Gap

Ignitor wire