3.6 Signal Connection- Current Loop

The basic CIO-DAC##-I current output circuit is shown in Figure 3-2. Loop power
is from an external power supply. The supply voltage is from 6V to 36V, with 24V
or 36V being typical choices.

Figure 3-2. Basic Current Loop

The 4 to 20 mA loop can be configured with either a floating power supply (Figure
3-3) or a floating load (Figure 3-4).

Figure 3-3. I-Loop, Floating Supply

Figure 3-4. I-Loop, Floating Load

5

+

-

4-20mA Control

LLGND

+

-

4-20mA Control

LLGND

Floating
Supply

+

-

Grounded
Load

4-20mA Control Board

+

-

4-20mA Control

LLGND

Supply

+

-

Load

4-20mA Control Board