beautypg.com

Measurement Computing CIO-DAC02 User Manual

Page 14

background image

CIO-DAC02 User's Guide

Functional Details

14

A minimum of 8 VDC and a maximum of 36 VDC external excitation voltage is used to power the loop. A
typical application would use a 24 V loop supply. The loop may use either a grounded load (the supply
"floats"), or a grounded supply, (the load "floats"). Both methods are shown in Figure 7.

4-20mA OUTPUTS - The 4-20 mA may be hooked up with either a
floating supply or a floating load. Both methods are shown here.

GROUNDED

LOAD

LOAD

+

-

+

-

4-20mA

4-20mA

LLGND

LLGND

FLOATING

SUPPLY

FLOATING

GROUNDED

SUPPLY

Figure 7. Loop grounding methods