beautypg.com

Appendix – MEGA Corp. MSC-OPS-1 User Manual

Page 54

background image

MSC/MST-OPS-1

31 Dec 2013

SECTION 7

Appendix

7-11

MSC/MST-OPS(CL)-1

31 Dec 2013

Once operations are complete:

7. FOAM Switch – OFF

8. Water Cannon – Flow water through the water

cannon nozzle with the FOAM switch off to flush
foam from the nozzle.

9. MONITOR/BFV Switch – OFF

10. Water Cannon Nozzle - STOW

Manual and remote adjustable nozzles must be
stowed pointing vertically to reduce wear on
water cannon joints. Leaving the nozzle in any
other position will cause increased wear on water
cannon joints and result in premature joint
failure.

11. PUMP Switch OFF

Engaging/disengaging the water pump above
LOW IDLE may result in water pump component
damage and reduced service life.

12. Cab Control SYSTEM/POWER Switch – OFF

N-10