8 specifications, Specifications – LSC Lighting GenVI User Manual
Page 33
![background image](https://www.manualsdir.com/files/795171/content/doc033.png)
GenVI Dimmer
Specifications
Operator Manual V1.0
Page 29
8 Specifications
Power Input
Nominal: 220-240 Volts.
3-phase star (380-415V). 50-60Hz
(Single phase operation possible. See section 2.3.1)
Operating range : Typically 190-260V, 45-65Hz
3-phase delta connection is available as a factory fitted option.
Control Inputs
DMX512 (1990) or DMX512-A (E1-11) and RDM (E1-20) via 5 pin XLR.
Outputs
Several types of output connections can be ordered:
Australian 3 pin sockets.
Powercon sockets.
Shuko sockets.
Harting 16 sockets.
Socapex.
Screw terminals.
Load Output per
Channel
10A or 13A maximum load per channel with each channel protected by a
RCBO (Residual Current Breaker with Overcurrent).
LSC’s proprietary Current Control Technology © (CCT) protects all
RCBO’s from nuisance tripping due to cold lamp inrush currents.
Duty Cycle
Rated at 100% across all channels simultaneously at 25°C ambient.
Construction
19 inch rack mounting. 3 RU (Rack Units) high.
Dimensions and
weights
Dimensions: 69 x 43 x 12cm
Box dimensions: 70 x 45 x 15cm