4.2

TrOublesHOOTing

power On light is not lit.

There is no power in the machine.

• Check mains fuses, replace blown fuses.

• Check mains cable and plug, replace defect parts.

The machine is not welding properly.

There are plenty of spatters during welding. Weld joint is porous or power supply is
insufficient.

• Check welding settings and adjust if needed.

• Check gas flow and gas hose connection.

• Check that earth clamp is properly fastened and that earth cable has no defects. Change

the position if necessary and replace defect parts.

• Check welding torch cable and connector. Tighten the connection and replace defective

parts.

• Check the consumable parts of welding torch. Clean and replace defect parts.

• Check mains fuses, replace blown fuses.

power source overheat indicator light is lit.

Power source is overheated.

• Check that there is enough free space behind the machine for cooling air circulation.
• Check cooling unit for water circulation, clean cooling unit filter and air grate. Add

cooling liquid if necessary.

For further information and assistance, contact your nearest Kemppi service workshop.

4.3

dispOsal OF THe MaCHine

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic

equipment, and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and taken to an appropriate

environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional

collection centre, per the instructions of local authorities or a Kemppi representative. By

applying this European Directive you will improve the environment and human health.