beautypg.com

Kemppi MLS 2300 ACDC User Manual

Page 16

background image

EN

welding panel aCX

– pulsed Tig and MinilOg function with memory

2.

1.

3.

4.

7.

8.

9.

11.

5.

10.

6.

12.

13.

14.

1.

4T-LOG and MINILOG function selections

2.

Search arc 5 – 90 % of welding current

3.

Start-current 80 – 150 %

4.

Minilog-current 10 – 150 % of welding current

5.

Tail arc 5 – 90 % of welding current

6.

Selection for spot, synergetic quick pulse and long pulse

7.

Spot time 0,0 – 10,0 s

8.

Pulse current 10 A – power source max.

9.

Pulse ratio 10 – 70 % of pulse time

10. Frequency 0.2 – 250 Hz DC-TIG, 0.2 – 20 Hz AC-TIG

11. Base current 10 – 70 % of pulse current

12. MEMORY, memory function

13. Selection of channel in memory function

14. SAVE/memory values
If wanted in SETUP-function you can disable search arc and tail arc functions. Hot Start (Soft

Start)- and Minilog -currents can be disabled by adjusting the values to 100 per cent (the same

as the welding current).

14

M

ast

er

Tig MLS 2300 A

CDC / © Kemppi O

y / 1112