beautypg.com

Kemppi MLS 2300 ACDC User Manual

Page 18

background image

EN

3.2.4 adopting the saved settings

1.

Select MEMORY by pressing the button.

2.

Select memory channel by pressing the CH button.

3.

Start welding.

3.2.5 remote control memory channels

Memory channels are selected by pressing simultaneously both REMOTE and CH button. With

the remote control you can retrieve saved settings on memory channels 1-5. The selected

channel is marked with a dot.

3.2.6 seTup functions

A so called SETUP state is included for modifying panel functions. You can enter the SETUP

state by pressing the SETUP button longer than normally. Exit is performed in the same way.

You can select the function (see list below) by pressing the arrow buttons and then change

the setting by turning the potentiometer. See SETUP-function table on the next page.

3.2.7 Foot pedal control r11F

First read ”ACS Welding Panel – Basic Functions” point ”Remote control” for installing the

remote control ready for operation. Foot pedal R11F is used in TIG welding, and its control

range is adjustable. The minimum value of control range is set with the panel potentiometer

when the pedal is not pressed, display shows ”LO”. Control range maximum is set similarly by

pressing first the PEDAL LO/HI button on the panel, display shows ”HI”. Welding is started with

a light press on the pedal, the arc ignites to the set minimum current. Welding current goes

to maximum when the pedal is pressed to the bottom. The arc is broken when the pedal is

released. Adjust again if necessary.

3.3

COOling uniT OperaTiOn MasTerCOOl 20

The operation of Mastercool cooling unit is controlled by the power source. The cooling unit

pump starts automatically when welding starts. Proceed as follows:

1.

Start power source.

2.

Check water level and input flow of the reservoir, add liquid if needed.

3.

If you use a water-cooled torch you can fill it with water by pressing WATER FILL button for

more than 2 seconds.

The pump operates for 4 another minutes after welding has been finished to cool the water to

the same temperature as in the machine surrounds. This reduces the need of service.

Thermal overload

The thermal overload light is lit, the machine stops and display shows COOLER when

temperature control of the machine has detected cooling water overheating. The cooling unit

fan cools down the water, and when the light goes out welding can be started again.

water flow signal

Display shows COOLER when water flow is blocked.

3.4

sTOrage

The machine must be stored in a clean and dry room. Protect the machine from rain and direct

sunshine in places where temperature exceeds +25 °C.

16

M

ast

er

Tig MLS 2300 A

CDC / © Kemppi O

y / 1112