Operation – Kemppi MLS 2300 ACDC User Manual
Page 11
EN
3.
OperaTiOn
NOTE!
Welding in places presenting an immediate fire or explosion hazard is forbidden!
NOTE!
Welding fumes may cause injury, take care of sufficient ventilation during welding!
3.1
welding prOCesses
3.1.1 MMa welding
With Mastertig MLS™ ACDC power sources you can use all electrodes suitable for direct and
alternating current welding between current limits of the power source. Both function panels
(ACS, ACX) can be used for electrode welding when MMA welding is selected.
3.1.2 Tig welding alternating Current
The Mastertig ACDC MLS™ power sources are specially designed for TIG welding aluminium
with alternating current (AC). We recommend using WC20 electrodes (grey) for AC welding.
The table is only given as a guide.
Welding current range AC
Electrode
Gas nozzle
Gas flow rate
min.
min.
maks.
WC20
ø mm
number
ø mm
Argon
A
A
A
l/min
15
25
90
1,6
4 / 5 / 6
6,5 / 8,0 / 9,5
6...7
20
30
150
2,4
6 / 7
9,5 / 11,0
7...8
30
45
200
3,2
7 / 8 / 10
11,0 / 12,5 / 16
8...10
40
60
350
4,0
10 / 11
16 / 17,5
10...12
The table and the panel scale are based on the use of WC20 (grey).
3.1.3 Tig welding with direct Current
DC welding is typically used when welding different grades of steel. We recommend using
WC20 electrodes (grey) for DC welding.
A directive electrode selection table for DC welding.
Welding current range
Electrode
Gas nozzle
Gas flow rate
DC
WC20
number
ø mm
Argon
A
ø mm
l/min
5 ... 80
1,0
4 / 5
6,5 / 8,0
5 ... 6
70 ... 140
1,6
4 / 5 / 6
6,5 / 8,0 / 9,5
6 ... 7
140 ... 230
2,4
6 / 7
9,5 / 11,0
7 ... 8
9
M
ast
er
Tig MLS 2300 A
CDC / © Kemppi O
y / 1112