4.3. TROUBLESHOOTING
Main power on light is not on
There is no power in the machine
Check mains fuses, replace blown fuses.
Check mains cable and plug, replace defect parts.
The machine is not welding properly.
There are plenty of spatters during welding. Weld joint is porous, power supply is insufficient.
Check welding settings and adjust if needed.
Check gas flow and gas hose connection.
Check that earth cable is properly fastened and has no defects. Change the position if
necessary and replace defect parts.
Check welding torch cable and connector. Tighten the connection and replace defective
parts.
Check the wear parts of welding torch. Clean and replace defect parts.
Check mains fuses, replace blown fuses.
Power source overheat signal lamp is lit.
Power source is overheated.
Check that there is enough free space behind the machine for cooling air circulation.
For further information and assistance, contact your nearest Kemppi service workshop.
4.4. DISPOSAL OF THE MACHINE
Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical equipment
that has reached the end of its life must be collected separately and returned to an
environmentally compatible recycling facility. As the owner of the equipment, you should
get information on approved collection systems from our local representative.
By applying this European Directive you will improve the environment and human
health!