Aktivering av innstillinger som er lagret, Fjernkontrollering av minnekanalene, Oppsett funksjoner – Kemppi MLS 1600 User Manual
Page 14: Oppbevaring, Taking the saved settings into use, Remote controlling memory channels, Set-up functions, Storage
![background image](https://www.manualsdir.com/files/792618/content/doc014.png)
© KEMPPI OY
14 – MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530
3.2.4. Taking the saved settings into use
1. Select MEMORY by pressing the button.
2. Select memory channel by pressing CH button.
3. Start welding.
3.2.5. Remote controlling memory channels
Memory channels are selected by pressing simultaneously both REMOTE and CH button. With
the remote control you can recall saved settings on memory channels.
3.2.6. Set-up functions
For modifying functions of panels a so called Setup state is included. This state is entered by
pressing the Remote (setup) button longer than normally. Exit is performed in the same way. You
can select the function (see list below) by pressing the arrow buttons and then change the setting
by turning the panel potentiometer.
3.3. STORAGE
The machine must be stored in a clean and dry room. Protect the machine from rain and keep it
away from direct sunshine in places where temperature exceeds +25 °C.
Display
Function
Factory setting
A1
Upslope with constant time setting /
gradient (steepness) setting
0 constant time
A2
Downslope with constant time setting /
gradient (steepness) setting
0 constant time
A3
TIG antifreeze off / on
1 on
A4
MMA antifreeze off / on
1 on
A5
MMA hot start pulse non adaptive / adaptive
0 non adaptive
A6
Downslope cut off on / off
0 on
A7
MMA no load voltage 80V / 40V
0 80 V
A8
2T downslope normal / cuts off by short switch action
0 normal
A9
Tacking automatics off / on
0 off
A10
Current at arc start steep / slightly sloped
0 steep
A11
Downslope linear / non linear
0 linear
A12
MMA -TIG method selection with remote control
off /on
0 off
A13
Search arc off / on
1 on
A14
Possibility to current freezing during
downslope off/ on
0 off
A15
Control of channels with torch up-down off / on
0 off
A16
Control of current with torch up-down is always active /
active only when selected with remote button
0 always active
A17
Not in use in Mastertig 2000 MLS
A18
Modified selection of cut off in MTL and MTM panels. For
downslope, press start switch and keep it down
(4T and Minilog)
0 normal
A19
Not in use in Mastertig 2000 MLS