beautypg.com

Aktivering av innstillinger som er lagret, Fjernkontrollering av minnekanalene, Oppsett funksjoner – Kemppi MLS 1600 User Manual

Page 14: Oppbevaring, Taking the saved settings into use, Remote controlling memory channels, Set-up functions, Storage

background image

© KEMPPI OY

14 – MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530

3.2.4. Taking the saved settings into use

1. Select MEMORY by pressing the button.
2. Select memory channel by pressing CH button.
3. Start welding.

3.2.5. Remote controlling memory channels

Memory channels are selected by pressing simultaneously both REMOTE and CH button. With

the remote control you can recall saved settings on memory channels.

3.2.6. Set-up functions

For modifying functions of panels a so called Setup state is included. This state is entered by

pressing the Remote (setup) button longer than normally. Exit is performed in the same way. You

can select the function (see list below) by pressing the arrow buttons and then change the setting

by turning the panel potentiometer.

3.3. STORAGE

The machine must be stored in a clean and dry room. Protect the machine from rain and keep it

away from direct sunshine in places where temperature exceeds +25 °C.

Display

Function

Factory setting

A1

Upslope with constant time setting /
gradient (steepness) setting

0 constant time

A2

Downslope with constant time setting /
gradient (steepness) setting

0 constant time

A3

TIG antifreeze off / on

1 on

A4

MMA antifreeze off / on

1 on

A5

MMA hot start pulse non adaptive / adaptive

0 non adaptive

A6

Downslope cut off on / off

0 on

A7

MMA no load voltage 80V / 40V

0 80 V

A8

2T downslope normal / cuts off by short switch action

0 normal

A9

Tacking automatics off / on

0 off

A10

Current at arc start steep / slightly sloped

0 steep

A11

Downslope linear / non linear

0 linear

A12

MMA -TIG method selection with remote control
off /on

0 off

A13

Search arc off / on

1 on

A14

Possibility to current freezing during
downslope off/ on

0 off

A15

Control of channels with torch up-down off / on

0 off

A16

Control of current with torch up-down is always active /
active only when selected with remote button

0 always active

A17

Not in use in Mastertig 2000 MLS

A18

Modified selection of cut off in MTL and MTM panels. For
downslope, press start switch and keep it down
(4T and Minilog)

0 normal

A19

Not in use in Mastertig 2000 MLS

This manual is related to the following products: