Lagre sveiseinnstillingene (mtm), Saving welding settings (mtm) – Kemppi MLS 1600 User Manual
Page 13
© KEMPPI OY
MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530 – 13
3.2.2.5. TIG welding panel MTM
– pulsed TIG and MINILOG function with memory
7. Minilog
26. Selection for Memory function (see 3.2.3.)
27. Selection for channel in memory function
28. Minilog 10 - 90% of welding current
29. SAVE
7. Minilog operation
When torch switch is pressed gas flow starts, when you release the switch current goes to search
arc. A quick press and current goes to welding current within the up-slope time. After a new short
press it goes to minilog operation and you can select two current levels, the welding current and
the minilog current, and you can move from one to the other by quickly pressing the torch trigger.
Press the torch trigger over 1 second and release it and current goes to downslope.
3.2.3. Saving welding settings (MTM)
MTM panel has 10 memory channels for user settings. The selections for saving are made on
MEMORY field. Not only welding parameters but also selections are saved in the memory. Stick
welding values can also be stored in memory channels. Proceed as follows:
1. Press MEMORY button twice and if the SET light starts blinking, the channel is free. If the
channel is in use then the led will remain on.
2. Select memory channel by pressing CH -button.
3. Select the parameters and press SAVE button
4. Press MEMORY button twice. ON led is lit.
5. Start welding and adjust settings if necessary.
If saved settings need to be changed, the lit led has to be moved from ON into SET position in
order to select parameters.Press the SAVE button. It is also possible to save the currently used
parameters in the panel by pressing SET when the memory function is in off state (no lights on).
Channel is cleared if MEMORY and CH buttons are pressed simultaneously in SET state.
26 27
28
7
29