beautypg.com

Kemppi MLS 1600 User Manual

Page 12

background image

© KEMPPI OY

12 – MASTER MLS™ 1600, MASTERTIG MLS™ 2000 / 0530

3.2.2.4. TIG welding panel MTX – pulsed tig functions

7. 4T-LOG
18. Selection for spot, synergic quickpulse and long pulse
19. Search arc 10 - 80% of welding current
20. Pulse current 10A - max.
21. Pulse ratio 10 - 70 % of pulse time
22. Frequency 0,2 - 300 Hz
23. Base current 10 - 70% of pulse current
24. Spot time 0 - 10 s
25. Tail arc 10 - 80% of welding current

7. Welding torch trigger 4T-LOG function (only MTX panel)

When torch switch is pressed current goes to search arc, after the switch is released current goes

to welding current within the up-slope time. When the switch is pressed again, current goes to

downslope and then to the tail arc. Current stops when the switch is released.

18. Spot

Spot function is practical when welding a definite spot. It can be used both in 2T and 4T. Enter

the spot time adjustment by pressing arrow button and when led lights you can choose the needed

spot time by turning pulse potentiometer.

18. Synergic quickpulse

Press the PULSE button twice and the synergic light turns on. Pulse parameters are automatically

calculated when mean welding current is selected. Other pulse selections are not necessary.

18. Long pulse

Long pulse method gives you a possibility to adjust all the pulse parameters (pulsing frequency,

pulse ratio, pulse current and pause current). You can also set the mean welding current which

results in a new pulse current value calculated using the set percentage values of pulse ratio and

pause current like when entering Pulse mode. When you adjust the pulse ratio percentage, pulse

current or pause current percentage a new mean welding current value is calculated and displayed

on the panel.

18

20

25

19

24

23

7

21

22

This manual is related to the following products: