14. selection of crater fill function (adaptive mode)

CRATER

FILL

When operating in adaptive mode and AUTOMATIC is selected from the mode selection

button 6, you can select CRATER FILL function. CRATER FILL function activates a pre‐set slope

timer at the end of the welding cycle and operates in either 2T or 4T gun switch mode when

the off signal is given.
15. selection for memory function

MEMORY

SAVE

1

2

3

4

When operating in either MANUAL or AUTOMATIC mode, you can store your welding

parameters using the MEMORY function. There are four MEMORY locations to choose from,

and you can store either MANUAL or AUTOMATIC welding setup in any channel location. To

store your welding settings, simply press and hold a MEMORY button for 5 seconds.
To recall the welding settings for future use, simple short press the MEMORY buttons. To

record new weld settings to a channel, repeat the long press sequence.
16. material thickness and weld shape display

mm

When operating in adaptive mode and AUTOMATIC is selected from the mode selection

button 6, the material thickness and weld shape is displayed, based on your input selections

for plate thickness in mm and weld shape. Adjust these values though control knobs 2 and

3. As you adjust the power control (2), you will see the graphic indicating plate thickness

become thicker or thinner, and as you adjust the arc length control (3) you will see the weld

shape change from convex, flat and concave. Select the desired settings and you are ready to

weld.