Kemppi RA User Manual
Page 25
EN
14. selection of crater fill function (adaptive mode)
CRATER
FILL
When operating in adaptive mode and AUTOMATIC is selected from the mode selection
button 6, you can select CRATER FILL function. CRATER FILL function activates a pre‐set slope
timer at the end of the welding cycle and operates in either 2T or 4T gun switch mode when
the off signal is given.
15. selection for memory function
MEMORY
SAVE
1
2
3
4
When operating in either MANUAL or AUTOMATIC mode, you can store your welding
parameters using the MEMORY function. There are four MEMORY locations to choose from,
and you can store either MANUAL or AUTOMATIC welding setup in any channel location. To
store your welding settings, simply press and hold a MEMORY button for 5 seconds.
To recall the welding settings for future use, simple short press the MEMORY buttons. To
record new weld settings to a channel, repeat the long press sequence.
16. material thickness and weld shape display
mm
When operating in adaptive mode and AUTOMATIC is selected from the mode selection
button 6, the material thickness and weld shape is displayed, based on your input selections
for plate thickness in mm and weld shape. Adjust these values though control knobs 2 and
3. As you adjust the power control (2), you will see the graphic indicating plate thickness
become thicker or thinner, and as you adjust the arc length control (3) you will see the weld
shape change from convex, flat and concave. Select the desired settings and you are ready to
weld.
23
© Kemppi Oy / 1336