beautypg.com

Kemppi GT02S User Manual

Page 12

background image

EN

Communication cables

Support the SuperSnake coupling and guide the filler wire into the SuperSnake liner.

Then carefully mate and connect SuperSnake to the wire feed unit connector. Secure the

SuperSnake by hand tightening the orange collar. The SuperSnake coupling transfers welding

power, shielding gas and gun trigger lines. In addition you must connect both cable plugs

to the FastMig or ProMig wire feed unit sockets (from MXF synchronisation kit W004030 or

ProMig ProSync 50 kit 6263121). This ensures wire feed motor synchronization, metering and

remote control functions. Align and connect the plugs to the sockets and lightly tighten by

hand. In ProSync applications, welding values are not shown. Instead, the display shows only

dashes – – – .

SuperSnake GT02S

SuperSnake GT02SW

3.6

autOmatiC wire Feed tO intermediate Cable and gun

WF #

1.

1.

WIRE INCH button

You are now ready to ‘Auto Load’ the filler wire. Ensure the FastMig or ProMig wire feed

mechanism pressure arms are in place and correctly adjusted. Press the WIRE INCH button on

the wire feed panel. MXF/PF system will automatically load the filler wire to the SuperSnake

feed mechanism, and through the gun connector block. There should be a small amount of

filler wire sticking out ready for gun connection.

NOTE!

In ProMig applications, the automatic Wire Inch function is not available. You must press

and hold the Wire Inch button or welding gun trigger, until the filler wire reaches SuperSnake.

10

SuperSnake GT02S, GT02SW / © Kemppi O

y / 1110

This manual is related to the following products: