Communication cables
Support the SuperSnake coupling and guide the filler wire into the SuperSnake liner.
Then carefully mate and connect SuperSnake to the wire feed unit connector. Secure the
SuperSnake by hand tightening the orange collar. The SuperSnake coupling transfers welding
power, shielding gas and gun trigger lines. In addition you must connect both cable plugs
to the FastMig or ProMig wire feed unit sockets (from MXF synchronisation kit W004030 or
ProMig ProSync 50 kit 6263121). This ensures wire feed motor synchronization, metering and
remote control functions. Align and connect the plugs to the sockets and lightly tighten by
hand. In ProSync applications, welding values are not shown. Instead, the display shows only
dashes – – – .
SuperSnake GT02S
SuperSnake GT02SW
3.6
autOmatiC wire Feed tO intermediate Cable and gun
WF #
1.
1.
WIRE INCH button
You are now ready to ‘Auto Load’ the filler wire. Ensure the FastMig or ProMig wire feed
mechanism pressure arms are in place and correctly adjusted. Press the WIRE INCH button on
the wire feed panel. MXF/PF system will automatically load the filler wire to the SuperSnake
feed mechanism, and through the gun connector block. There should be a small amount of
filler wire sticking out ready for gun connection.
NOTE!
In ProMig applications, the automatic Wire Inch function is not available. You must press
and hold the Wire Inch button or welding gun trigger, until the filler wire reaches SuperSnake.