Kemppi GT02S User Manual
Page 10
![background image](https://www.manualsdir.com/files/792572/content/doc010.png)
EN
3.2
mOunting and lOCking OF wire SpOOl
Ensure quality filler wire is loaded to the wire feed cabinet. Check that the correct wire guide
tube and wire drive rolls are selected and fitted for the filler wire type used.
NOTE!
Check that the filler wire spool is correctly mounted and locked into position. Ensure the
spool is not damaged or deformed in such a way that it can rub or chaff against the internal
surface of the wire feed unit chassis or door. This may result in increased drag, impacting on weld
quality. This may also result in long term wire feed unit damage, rendering the unit unserviceable
or unsafe to use.
3.3
lOading the Filler wire and autOmatiC Feed
Automatic wire feed makes wire spool changes faster. When changing the wire spool, the
pressure of feed rolls need not be released. Simply ensure that the groove of the feed roll
matches the diameter of filler wire used. Release the wire end from the spool and cut off any
deformed section. Be careful the wire does not spill from the spool sides. Straighten about
20cm of filler and present the filler wire tip to the back of the wire feed rolls and press the wire
inch button on the wire feed panel.
8
SuperSnake GT02S, GT02SW / © Kemppi O
y / 1110