Appendix E: Troubleshooting

Failure Possible

reasons

After plugging in power, turning on the power switch,

“POWER” light in front Panel does not turn on, and fan

does not work.

1)

Power cable is damaged

2)

Power supply is damaged

After plugging in power, turning on the power switch,

“POWER” light in front panel turn to green while fan does

not work.

1)

Front panel cable is damaged

2)

Fan is broken.

After plugging in power, turning on switch, “POWER” light

turn to green, the indicator lights in the panel turn on at the

same time, but fan does not work.

The ATX plug in main board is

not attached well.

DVR continuously reboots after start up, and makes a sound

like “di” every 10 seconds.

1)

Upgraded using wrong

firmware

2)

Compression board has

problems.

3)

Main board has problems.

There are no images in the monitor connected with VOUT

after DVR is started.

1)

The cable connected with the

monitor is damaged

2)

Real board of DVR has

problems.

3)

Main board of DVR has

problems.

Cannot find the hard disk in reboot process.

1)

Hard disk cable is damaged

2)

The power cable of hard disk

is not connected.

3)

Hard disk is damaged

DVR can not control PTZ through RS-485 port.

1)

RS-485 cable is not

connected correctly or is

damaged

2)

PTZ parameters error.

3)

RS-485 port of DVR is

damaged

Client software can not view DVR live image.

1)

Network error.

2)

Wrong DVR setup (wrong

IP, port number, username or

password, etc).

3)

Old player SDK (playm4.dll)

Notes:

1) Place the DVR in well ventilated area so that it operates within the recommended range of

temperature and humidity as in specifications.

2)

If the circuit board gets wet, dust on circuit board can cause a short circuit. The circuit board, plug

and socket, housing fan and housing should be cleaned by brushing.