beautypg.com

Datalogic Scanning C-BOX 300 User Manual

Page 22

background image

C-BOX 300/310

2

The C-BOX 3X0 spring clamp connector pinouts are indicated in the following table.

Refer to the scanner Installation Manual for details.


Pin Name
1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

9…12, 20, 33, 34, 40 Reserved
35 TXA
37 RXA

DS2100A
DS2400A

DS4600A Matrix-2000™ Matrix-1000™

21

OUT1+ OUT1+ OUT1+ NC

22

OUT

REF

OUT1- OUT1- NC

23

OUT2+ OUT2+ OUT2+ NC

24

OUT

REF

OUT2- OUT2- NC

25 NC

Reserved

OUT3+

OUT3+

26 NC

Reserved

OUT3-

OUT3-

27

EXT TRIG+

EXT TRIG+

EXT TRIG A

EXT TRIG A

28

EXT TRIG-

EXT TRIG-

EXT TRIG B

EXT TRIG B

29 NC

IN1+

IN

2A

NC

30 NC

IN1-

IN

2B

NC

31 NC

IN2+

NC

NC

32 NC

IN2-

NC

NC

36 RTSA

GND

NC

NC

38 CTSA

SGND

AUX

GND

GND

39 SGND

SGND

GND

GND


NOTE

Pin 7 or 8 should be connected to the earth ground.

Pins 13… 19 are not present in the C-BOX 3X0 models.

10

This manual is related to the following products: