beautypg.com

Ensign 40-2, Part 1 technical information – Insinger Ensign 40-2 User Manual

Page 4

background image

PART 1 TECHNICAL INFORMATION

®

www.insingermachine.com 800-344-4802

3M 0808

PRINTED IN USA

Information and specifications subject to change without notice

Note: For all rough in connections see Installation and Layout Detail Drawing.

SPECIFICATIONS
CONSTRUCTION -

Hood and tank constructed of 16 gauge 18-8 type 304 S/S. Hood unit of all welded seamless

construction. All internal castings are non-corrosive lead free nickel alloy or bronze.

DOORS -

Two opening operating doors. Operating doors have fingertip control, rotating on S/S bracket. Doors formed of

18 gauge S/S.

PUMP -

Centrifugal type “packless” pump with a brass petcock drain. Construction includes ceramic seal and a balanced

cast impeller on a precision ground stainless steel shaft, extension or sleeve. All working parts mounted as an assembly and

removable as a unit without disturbing pump housing. One 1/2 HP motor, standard horizontal C-face frame, drip proof, internally

cooled with ball-bearing construction.

CONTROLS -

Side-mounted control cabinet, housing motor controls and overload protection, transformer, contactors

and all dishwasher integral controls. All controls safe low voltage 24 VAC.

SPRAY SYSTEM -

Wash and rinse spray systems made of 18-8 type 304 S/S pipe.

WASH -

Power wash arm above with 14 high pressure action cleansing slots and 6 power wash arms below, each designed

with 5 high pressure action cleansing slots. The slots are precision milled for water control producing a fan spray. Wash arms

are removable without the use of tools.

FINAL RINSE -

1 spray body above designed with 4 power rinse nozzles and 1 power rinse coil below designed with

6 nozzles.

DRAIN -

Overflow assembly with skimmer is removable without use of tools for drain line inspection. Heater protected by low

water level controls.

Capacity

per hour

Final rinse

consumption

at 20 psi min.

Exhaust hood

requirement

Peak rate

drain flow

Shipping

weight

Current draw

amps

Steam

Electric

w/o booster

Tank capacity

Motor size

Electric usage

Final rinse

peak flow

at 20 psi min.

43 racks

720 dishes

34 gals./hr.

0.75 gals./rack

N/A

9 gals./min.

400 lbs.

8.1 gals.

1/2 hp (wash)

1.5 kw wash tank

6 kw booster 40° rise

12 kw booster 70° rise

6 lbs./hr tank

22 lbs./hr rem. booster 40° rise

43 lbs./hr rem. booster 70° rise 4.1 gals./min.

Steam consumption

at 20 psi min.

115/1/60 ................... 10.7 .................... 24.0

208/3/60 .....................2.9 ...................... 7.1

240/1/60 .....................5.6 .....................11.3

240/3/60 .....................2.6 ...................... 6.2

380/3/50 .....................1.6 ...................... 3.9

480/3/60 .....................1.4 ...................... 3.1

ENSIGN 40-2

CSI

- 1

1400

2

Ensign_40-2_TM2009