PART 3 MAINTENANCE AND REPAIR PROCEDURES

®

www.insingermachine.com 800-344-4802

13

NOTE:

The overfill timer MUST be adjusted during

initial start-up. Adjustment depends on

water fill pressure. The water level MUST

be 1/4” below the lip of the overflow tube.

Adjust by increasing or decreasing the

potentiometer on the level timer.

Motor Overloads

All motors used on Insinger Machines are provided

with motor overloads. Motor overloads are adjusted

when the machines are factory tested. Should it be

necessary to adjust the motor overloads in the field

first verify the motor current draw for the voltage the

machine is using.
Using the Control Panel Component Layout Dwg.

located in Section 4 to identify the overload, adjust by

turning the dial to the appropriate AMP draw.

Level System

The level control system consists of one overfill timer

(P/N DE7-35) and one level float (P/N DE5-60) per

tank.
When the system is powered-up, the tank(s) will

begin to fill (assuming no water is in the tanks).
When the level float is actuated, the overfill timer

begins to time-out and continues the filling process

until the tank(s) is full.
Also consists of a Hi-Limit switch in electric heated

unit. Hi-Limit in series with float. Inspect Hi-Limit for

damage. Be careful when cleaning not to damage it.

NOTE:

Dirty level floats will cause the tank heat to

energize with no water in the tanks.

LEVEL FLOATS MUST BE CLEANED

DAILY.