To do factory reset, please follow the below five steps:
1. Press MENU button to enter main menu.
2. Select the item SETUP.
3. Select the item Factory Reset.
4. Follow the instruction to turn the direction button, the screen will refresh.
5. Power off the monitor, and must wait for at least 5 seconds, then restart the monitor.
The monitor resets to factory preset.
● Remote Control
1. Hardware connection
Connect the monitor’s RS-232 serial port to the computer to remote control the
monitor by universal serial communication software.
2. Software Configuration
Start communication software, configure the serial communication parameters,
sending communications test command, if the return value is correct, you can send
control command.
Serial port settings:
Baud Rate: 19200
P a rity: None
Data bits: 8
S top bit: 1
Flow Control: None
Communications test:
Communications test
command
Return value
Description
BE EF 01 05 00 D1 FA 01
02 00 00 00
1E BE EF 01 04 00 37 3D 01 02
00 01
Return value is correct, the
communication setup is normal