7.2

Interconnect Cable

Pos: 36 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3

7.2.1

Cat X

A point-to-point connection is required. Operation with several patch fields
is possible. Routing over an active network component, such as an
Ethernet Hub, Router or Switch, is not allowed.
 Avoid routing Cat X cables along power cables.
 If the site has 3-phase AC power, try to ensure that CPU Unit and

CON Unit are on the same phase.

To maintain regulatory EMC compliance, correctly installed shielded Cat X
cable must be used throughout the interconnection link.

To maintain regulatory EMC compliance, all Cat X cables need to carry
ferrites on both cable ends close to the device.

Type of Interconnect Cable

The KVM Extender requires interconnect cabling specified for Gigabit
Ethernet (1000BASE-T). The use of solid-core (AWG24), shielded, Cat 5e
(or better) is recommended.

Cat X Solid-Core Cable
AWG24

S/UTP (Cat 5e) cable according to EIA/TIA-
568-B. Four pairs of wires AWG24.
Connection according to EIA/TIA-568-B
(1000BASE-T).

Cat X Patch Cable
AWG26/8

S/UTP (Cat 5e) cable according to EIA/TIA-
568-B. Four pairs of wires AWG26/8.
Connection according to EIA/TIA-568-B
(1000BASE-T).

The use of flexible cables (patch cables) type AWG26/8 is possible,
however the maximum possible extension distance is halved.

Pos: 37 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X)_Kabellänge 473-xx @ 5\mod_1278928498808_6.doc @ 42798 @

Maximum Acceptable Cable Length

Cat X Solid-Core Cable
AWG24

40 m (120 ft) at 1920x1200 and 1600x1200
50 m (150 ft) at 1280x1024 and less

Cat X Patch Cable
AWG26/8

20 m (60 ft) at 1920x1200 and 1600x1200
30 m (90 ft) at 1280x1024 and less

See Chapter 7.3.3, Page 32 for a list of specifically tested cables with an
optimum range.