DSXi KVM Extender

24

2011-02-23

5.2

DDC Settings

By default, the device sends the factory preset DDC information to the
CPU. This information is sufficient in most cases.

CPU Unit and CON Unit offer the following DIP switch settings to control
the administration of the DDC information:

CPU Unit

DIP

Function

Switch
Position

Switch down

Switch up

Not used

Send stored DDC information to CPU (default: factory preset
DDC information).
Allow reading of DDC information from the attached monitor.

Reset and only ever send the factory default
DDC information

CON Unit

DIP

Function

Switch
Position

Switch down

Switch up

Not used

Prevent reading of DDC information from the attached
monitor

Allow reading of DDC information from the attached monitor

Reading of DDC information is performed during operation (see
Chapter 6.2, Page 27).

If DIP switch 3 on the CPU Unit is in upper position the CPU will only ever
be sent the factory preset DDC information.