3 system settings (sdo index 0x4000 - 0x403f) – ifm electronic JN2100 v.2.2.0 User Manual
Page 17

UK
Inclination sensor JN
17
SDO
index
Sub-
index
Type
Value
Unit
r/w
Reset
0x2048
0x0
u8
Axis selection for Veff & aPeak
X axis active -> bit 2 = 1
X axis not active -> bit 2 = 0
Y axis active -> bit 1 = 1
Y axis not active -> bit 1 = 0
Z axis active -> bit 0 = 1
Z axis not active -> bit 0 = 0
rw
0x2049
0x0
u8
FIR filter for vibration measurement
0: FIR deactivated
1: FIR bandpass filter 0.1 - 1 Hz
2: FIR bandpass filter 0.1 - 10 Hz
3: FIR bandpass filter 1 - 10 Hz
4: FIR bandpass filter 2 - 400 Hz
5: FIR bandpass filter 10 - 400 Hz
rw
0x204A
0x0
u8
Measuring range for Veff & aPeak and
raw acceleration without DC part
0 : ± 2g
1 : ± 4g
2 : ± 8g
rw
0x207F
0x0
u8
Factory reset
1: make factory reset
rw
0x3000
0x0
ASCII
Programming key
rw
7.6.3 System settings (SDO index 0x4000 - 0x403F)
SDO
index
Sub-
index
Type
Value
Unit
r/w
Reset
0x4004
0x0
u8
MEMS self-test
Number sub-indices
r
0x4004
0x01
u8
Flag to activate the self-test
Flag = 1
→
start self-test
rw