Test 2 — power board voltage checks, Powermax30 – Hypertherm Powermax30 Service Manual User Manual
Page 55

MAINTENANCE
3-16
powermax30
Service Manual
Test 2 – power board voltage checks
With the power ON, use a meter to verify the voltages at the J7 pins listed in the following table to be certain that
the power board is functioning correctly. If any of the values are incorrect, replace the power board.
Note:
All values can be ±10%.
J7 pin number to
ground
Test
Expected value
19
VACR (rectified AC line voltage)
0.86 V @ 120 line voltage
1.87 V @ 230 line voltage
21
VBUS (DC bus voltage)
2.28 VDC @ 375 VBUS
18
IPFC (input current)
< 0.1 VDC
20
IFB (output current)
< 0.1 VDC
22
ITF (transfer current)
< 0.1 VDC
5
3.3 VDC
3.3 VDC ±5%
7
5 VDC
5 VDC ±5%
12
24 V sense pin
2.2 VDC
16
Start signal
3.2 VDC closed
0 VDC open
Note:
To test the values at pin 16, you must have the torch and power supply positioned such that you can
safely pull and release the torch’s trigger.
Ground to the ground wire
clip or to the heat sink
Caution:
Do not use -VBUS as ground. Doing so could destroy the power supply. Instead
ground to either the ground wire clip on the rear endcap or to the heat sink as
shown below.
- EDGE Pro Ti Shape Cutting Control Rev.2 (288 pages)
- 80669J Rev.3 (304 pages)
- HD3070 Plasma Arc Cutting System w/ Manual Gas Console (281 pages)
- MAXPRO200 Rev.2 (294 pages)
- MicroEDGE Pro Shape Cutting Control Rev.2 (182 pages)
- HPR260 Auto Gas Preventive Maintenance Program Rev.4 (288 pages)
- Powermax1650 (317 pages)
- Shape Cutting Control (66 pages)
- PHC Sensor (58 pages)
- HTA Rev 6.00 Operators Manual (212 pages)
- HTA Rev 7.00 Install Guide (242 pages)
- THC Control Board Replacement (13 pages)
- THC Plasma Interfacer Upgrade (9 pages)
- THC X-Y Table Product Configuration (20 pages)
- D845GERG2 (128 pages)
- MRT2 (64 pages)
- MRT (98 pages)
- Duramax Hyamp Long Handheld Torches (92 pages)
- Duramax Hyamp Robotic Torch (74 pages)
- HyIntensity Fiber Laser Rev.3 (240 pages)
- PCBS-0124 (70 pages)
- SuperMicro 370SBA 533Mhz (90 pages)
- LR2075 (56 pages)
- Phoenix 8.0 (585 pages)
- LH2125 (60 pages)
- HD3070 w/ Automatic Gas (35 pages)
- HD3070 w/Manual Gas (43 pages)
- HD4070 Rev.8 (278 pages)
- HD4070 Product Configuration (88 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (32 pages)
- HPR800XD Manual Gas Preventive Maintenance Program Rev.1 (33 pages)
- HPR800XD Manual Gas Rev.2 (368 pages)
- HPRXD Short Torch with Integrated Lead Rev.1 (30 pages)
- HT4001 (59 pages)
- DuraChill 5 HP Air-Cooled Chiller For Hypertherm (29 pages)
- HT4001 Air Injected Water Muffler System (40 pages)
- H601 Power Supplies (62 pages)
- MAX200 Remote Switch (9 pages)
- HT4100 Plasma Arc Cutting System Operating (50 pages)
- HT4001 Plasma Arc Cutting System (259 pages)
- HSD130 HySpeed Plasma (233 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.7 (53 pages)
- HySpeed HT2000 Plasma Arc Cutting System Rev.27 (289 pages)
- MAX200 Water Muffler (39 pages)
- HT2000LHF Product Configuration (23 pages)