beautypg.com

Power supply, Dimensions and weight, Powermax30 – Hypertherm Powermax30 Service Manual User Manual

Page 37: Specifications 2-2, Service manual

background image

SPECIFICATIONS

2-2

powermax30

Service Manual

Power supply

Rated open circuit voltage (U

0

)

240 VDC

Rated output current (I

2

)

15 A to 30 A

Rated output voltage (U

2

)

83 VDC

Duty cycle at 40°C, U

1

=120 VAC

35% (I

2

= 30 A, U

2

= 83 V)

(See data plate on power supply for more

60% (I

2

=2 3 A, U

2

= 83 V)

information on duty cycle and for IEC ratings.)

100% (I

2

= 18 A, U

2

= 83 V)

Duty cycle at 40°C, U

1

=200-240 VAC

50% (I

2

= 30 A, U

2

= 83 V)

75% (I

2

= 24 A, U

2

= 83 V)

100% (I

2

= 21 A, U

2

= 83 V)

Operating temperature

14° to 104° F (-10° to 40°C)

Storage temperature

-13° to 131° F (-25° to 55°C)

Power factor (120 V — 240 V)

0.99 — 0.97

Input voltage (U

1

)/ Input current ( I

1

) at

120 V / 26 A

rated output (U

2 MAX

, I

2 MAX

)

200-240 V / 15.5-13 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free

99.995 % pure

Minimum required gas inlet flow and pressure

3.5 scfm @ 65 psi (99.1 l/min @ 5.5 bar)

Recommended gas inlet flow and pressure

4.0 scfm @ 80 psi (113.3 l/min @ 5.5 bar)

Dimensions and weight

Weight includes the hand torch

and 15 ft (4.57 m) lead.

20.65 lb

9.37 kg

13"

(330 mm)

5.5"

(140 mm)

10.5"

(267 mm)

11.5"

(292.1 mm)