beautypg.com

Control board leds, Powermax30 – Hypertherm Powermax30 Service Manual User Manual

Page 51

background image

MAINTENANCE

3-12

powermax30

Service Manual

Problem

This may mean

Cause

Solution

The cut quality is poor
or the cut does not sever
the metal.

The consumables are
worn, there is a poor
work lead connection,
the output from the
power supply is too low,
or the power board is
producing low current.

• The consumables need

to be replaced.

• The work lead may be

damaged or not properly
connected to the work
piece.

• The amps adjustment

knob may be set too
low.

• The power board may

be faulty.

• Inspect the consumables

and replace if necessary.

• Inspect the work lead for

damage. Reposition it and
clean the work surface to
ensure good contact.

• Check the amps

adjustment knob setting. If
your input circuit is 120 V,
20 A; 120 V, 30 A; or 240
V, 20 A , turn the knob to
the highest setting.

The pilot arc extinguishes
when you move the
plasma arc off the work
piece while still pulling the
torch’s trigger.

The continuous pilot arc
feature is not working.

The power board or the
control board may be
faulty.

Perform tests 2 and 3 to

verify that the power
board is functioning
properly. If the power
board is faulty, replace it.
Otherwise, replace the
control board.

Troubleshooting guide (continued)

Control Board LEDs

The Powermax30 control board (PCB1) has 4 diagnostic LEDs.

Control board

Ribbon cable