beautypg.com

Cnc interface cable - power supply to cnc -18, Cnc interface cable - power supply to cnc, Installation – Hypertherm HD4070 Rev.8 User Manual

Page 59

background image

INSTALLATION

0

3-18

HD4070

Instruction Manual

CNC Interface Cable - Power Supply to CNC

10

Part No.

Length

123437

10 ft (3 m)

123438

20 ft (6 m)

123439

25 ft (7.5 m)

123440

30 ft (9 m)

123441

40 ft (12 m)

Part No.

Length

123442

50 ft (15 m)

123443

75 ft (23 m)

123444

100 ft (30.5 m)

123445

150 ft (46 m)

1X3

*

See notes on next page

Power

Supply

CNC-

Input/

Signal Name

End

Color

End

Function

Output Notes

NC

Blue

NC

Not connected

*

Interlock -

19

White

19

Allows installation of an emergency stop switch (normally closed).

Input

Interlock +

37

Black

37

If CNC interlock is not used, install a jumper wire to close.

Input

Motion

18

White

18

Verifies to CNC that a pierce delay is complete and notifies CNC to

Output

1

Motion

36

Orange 36

start movement of the cutting machine. For multiple plasma systems on

Output

the same cutting machine, this signal should be logically ANDed from all
connected plasma systems.

Transfer

17

Green

17

Notifies the CNC that a successful arc transfer has occurred. This signal is

Output

1

Transfer

35

Brown

35

similar to motion, but does not include the programmed pierce delay time.

Output

Ground

16

Green

16

Ground

34

Yellow

34

Ground

15

Green

15

Machine Cable Installed +

33

Blue

33

Verifies that the CNC machine cable has been installed.

Input

3

Machine Cable Installed -

14

Green

14

Input

System Error +

32

White

32

Notifies the CNC motion controls that a plasma system error has occurred

Output

2

System Error -

13

Green

13

Actual error can be queried from serial interface.

Output

Spare Output 1 +

31

Orange 31

Spare output

Output

2

Spare Output 1 -

12

Red

12

Output

Spare Input 1 +

30

Brown

30

Spare input

Input

3

Spare Input 1 -

11

Red

11

Input

Spare Input 2 +

29

Yellow

29

Spare input

Input

3

Spare Input 2 -

10

Red

10

Input

Retract Complete +

28

Blue

28

Verifies to the CNC that the torch has retracted.

Output

2

Retract Complete -

9

Red

9

Output

Spare Output 2 +

27

Green

27

Spare output

Output

2

Spare Output 2 -

8

Red

8

Output

Spare Output 3 +

26

White

26

Spare output

Output

2

Spare Output 3 -

7

Red

7

Output

Ready to Fire +

25

Orange 25

This signal is used in multiple plasma systems. It notifies the CNC that the

Output

2

Ready to Fire -

6

Black

6

THC completed the IHS cycle and preflow is complete, indicating that the

Output

torch is ready to fire. This signal and the CNC Plasma Sync signal are
used together. For multiple plasma systems on the same cutting machine
this signal should be logically ANDed to indicate that all machines are ready.

Plasma Sync +

24

Brown

24

This signal is used in multiple plasma systems. It delays torch firing, but

Input

3

Plasma Sync -

5

Black

5

allows the preflow gases to flow. This signal and the ready-to-fire signal

Input

are used together. For multiple plasma systems on the same cutting
machine, this signal should be removed simultaneously to all connected
plasma systems so all torches will fire simultaneously.

Corner Hold +

23

Yellow

23

On systems with a command THC installed, When this signal is active it

Input

3

Corner Hold -

4

Black

4

override the arc voltage control and hold the torch height constant.

Input

System Start +

22

Blue

22

Initiates the start of a programmed plasma system cut cycle. This signal

Input

3

System Start -

3

Black

3

must be maintained for the duration of the cut. For multiple plasma

Input

systems on the same cutting machine, this signal should be activated
simultaneously to all machines.

CNC TX +

21

Green

21

RS - 422 serial transmitter. Transmits data from CNC to plasma system.

Input

3

CNC TX -

2

Black

2

Used to set up plasma process information and query for plasma status

Input

information. See serial command list for full description.

CNC RX +

20

Red

20

RS - 422 serial receiver. Receives data from plasma system to CNC

Output

CNC RX -

1

Black

1

controls. Used to report plasma system status and error information in

Output

response to commands from the CNC controller. See serial command list
for full description.

T