MAINTENANCE

5-40

HD4070

Instruction Manual

3

Phase Loss Detection Board PCB1 Status Indicators and Operation

Operation

The phase-loss detection circuit checks the incoming voltage and verifies that the voltages between the 3-wire
inputs are within +/- 15% of each other.

• After contactor CON1 closes, opto-coupler U

1

on PCB1 is activated, shorting pins 1&2 of PL1 together and

illuminating LED1.

• If LED1 does not illuminate:

• Verify that voltages across points A B and C, phase-to-phase are approximately 255 VAC. If voltages are

not within +/- 15%, LED1 will not illuminate. Check the incoming line voltage and the contacts on CON1.

• Check PCB1 fuses F1-F3. If any of the fuses are open, then PCB1 is faulty.

• Check jumper on P2 and verify that the jumper is set for 211V.

Phase-loss board PCB1 location on chopper CH2
See page 6-3 for location of CH2.

LED1

U1

A

B

C

F1

F2

F3

P2

P2 Jumper
for 211V