beautypg.com

Hypertherm Shape Cutting Control User Manual

Page 62

background image

Mariner

56

The Mariner Shape Cutting Control is designed with all machine interface
connections passing through the pedestal mount at the base of the enclosure.
Motion and I/O are supported via the fiber optic communication ring of the
SERCOS Interface.

The information contained in this section is intended to provide the basic
information for connection of the Mariner Shape Cutting Control to the cutting
table. Each machine interface will vary slightly based on the cutting table
configuration and features.

AC Input Pinout

TB connector

Description

101

110VAC or 220VAC Input (Hot)

102

110VAC or 220VAC Input (Neutral)

AC

Power

Ground


Recommended Wire
14 AWG or greater

E-Stop

The E-stop Switch provides normally open contacts rated at 20VAC/500mA
minimum to 250VAC/6A maximum.

TB connector Description
103 Contact

Closure

104 Contact

Closure

Diagram Location Din-02