beautypg.com

Hypertherm Shape Cutting Control User Manual

Page 56

background image

Voyager III

50

11

Channel /Z Input

12

Field Common

13

Field Common

14

Servo Output Common

15

Drive Enable Out ( relay contact )

Note: Cable Shields should be connected to chassis ground.

Drive/ Encoder Input Mating Connector
Connector: 15C D-Sub Amp # 25206-3 or equivalent
Backshell: Amp #748676-2 or equivalent
Pins: Amp #5-66506-9 ( 20-24 AWG ) or equivalent

Note: Wiring pattern continues for additional Axes

Analog Connection Pinout

Note on analog connector: For opertional flexibility, inputs and outputs have a
shared logic and are provided in both positive logic (+24VDC) and negative logic
(24VDC common).

In this application shared I/O means that a single I/O assignment is offered at
three locations.

Example: Output 15 could be assigned as the I/O connector a Nozzle Contact
Enable. Once assigned in software, this output signal would be available as:

- A positive logic output on second I/O connector Pin 20
- A positive logic output on analog connector Pin 7
- A negative logic output on analog connector Pin 8

Analog 1
Pin # Designation

Description

1

Analog 1 +

Analog Input ( 0-10VDC)

2

Analog 1 -

Analog Common

3 +24VDC
4

Duplicate Input 15

Positive logic shared input 15

5 Field

Common

6

Alternate Input 15

Negative logic shared input 15

7

Duplicate Output 15

Positive logic shared output 15

8

Alternate Output 15

Negative logic shared output 15

9 Field

Common


Note: Wiring pattern continues for Analog 2-6
Assignable shared I/O locations are 15, 16, 31, 32, 47, 48